DIAMETER RANGE: | Inner Diameter between 50 mm and 1200 mm according to ISO 5167, ASME MFC-3M |
FLOW RANGE: | 200000 ≤ ReD |
PRESSURE RANGE:
| Up to Sch XXS according to ASME B36.10M for piping Up to 2500 Lbs. according to ASME B16.5 for fittings |
CONNECTION TYPES: | Weld End according to EN 9692-1 or ASME B16.25 Flanged End according to EN 1092-1 or ASME B16.5 Other type of connection upon request |
MATERIAL: | Any type of steel body including throat of the primary device according to system requirements |
MEDIUM: | Water, Steam, Air, Natural Gas, Combustion Gas, Hydrogen, Nitrogen, Oil, Oven Gas and any other fluid of which thermophysical properties are known |