Data
General specifications:
- Measuring value error
– 0.4 % of rate, Option for 0.3% or 0,2% - Nominal diameter
– DN 1 to 100 (1/25 to 4 in.) - Process connection
– Weld stubs, threaded pipe connections, Tri-clamps, wafer-type, flanges, external threads, flanges in accordance with DIN/EN, ASME, JIS - Nominal pressure
– PN 10 to 40, ASME CL 150, 300 - Lining
– PFA vacuum stable - IP rating
– IP67 or IP68 - Fluid temperature
– Up to 180 °C (356 °F) - Communication
– HART, PROFIBUS DP, Modbus - Process diagnostics
– Empty pipe, gas bubbles, electrode impedance, conductivity, sensor temperature - Certificates
– 3A, FDA approved materials