Data
General specifications:
- Application
– Clean liquids, gases and steams - Mounting
– Vertically, in line - Connections
– 1/2 to 4 in., flanged, hygienic (DIN, SMS), vertical - Flow ranges
– Water flows: 0.028 to 120 m3/h - Flow turndown
– Typically 10:1 - Operating pressure
– Up to 100 bar (1450 lbf/in 2 g) - Operating temperature
– Up to 400 °C (752 °F) - Accuracy
– Class 1.6 (Class 2.5: PTFE line tubed opt.) - Alarms
– Slot sensors, up to 2 off - Tube material
– Stainless steel, optional PTFE lined - Float material
– Stainless steel, optional PTFE lined/float damping